| SLAN® Real-Time PCR system |
| |
|
|
| Specifications of the system |
| |
| PRODUCT MODEL |
SLAN® |
| SAMPLE CAPACITY |
48×0.2 ml TUBES |
| CHANNELS |
3 Channels |
| EXCITATION FILTERS |
470nm, 530nm, 630nm (585nm option available instead of 630nm) |
| DETECTION FILTERS |
530nm, 565nm, 665nm (620nm option available instead of 665nm) |
| FLUOROPHORES DETECTED |
FAM, SYBR Green, VIC, HEX, JOE, TET, ROX
Texas Red, CY5 |
| TEMPERTURE RANGE |
4℃-99℃ |
| HEATING RATE (MAX) |
3℃/S |
| COOLING RATE (MAX) |
2℃/S |
| TEMPERTURE ACCURACY |
±0.3℃ |
| TEMPERTURE UNIFORMITY |
±0.3℃ |
| OPERATING SYSTEM |
Win2000/XP professional |
| POWER SUPPLY |
220-240 VAC 50/60Hz |
| ENERGY CONSUMPTION |
500VA (Computer system excl.) |
| DIMENSIONS (W×D×H) |
38cm×50cm×126cm |
| WEIGHT |
15kg (computer system excl.) |
| LICENSE |
SFDA, CE, TUVISO13485:2003 |
|
| |
|
| Application of SLAN® |
|
| ● Pure science studies |
| ● Analysis of gene expression |
| ● Analysis of genotype |
| ● Clinical applications |
| ● Diagnosis of pathogens |
| ● Tumor typing/drug resistance assessment |
| ● Genetic screening |
| ● Food hygiene inspection |
| ● Food and livestock import/export testing |
| ● Food safety assessment |
| ● Public health safety and epidemiology |
|
| |
|
SLAN®-96P Real-Time PCR System |
| |
 |
|
| Specifications of the system |
|
| PRODUCT MODEL |
SLAN®-96P |
| SAMPLE CAPACITY |
96wells(dual 48/48 reaction module) |
| SAMPLE SIZE |
15~50ul |
| CONSUMABLE |
0.2ml PCR tubes,8-tube strips,48-well plates |
| PARALLEL RUNNING MODE |
Dual reaction blocks(running 2 tests independently) |
| TEMPERTURE RANGE |
4℃-99℃ |
| MAX RAMP RATE |
4.5℃/S |
| TEMPERTURE ACCURACY |
+/-0.1℃ |
| TEMPERTURE UNIFORMITY |
+/-0.1℃ |
| THERMAL CYCLING SYSTEM |
Peltier-based system |
| TEMPERATURE CONTROL MODE |
Tube control/Block control |
| LIGHT SOURCE |
LED(maintenance-free) |
| DETECTOR |
High sensitivity photoelectric sensor |
| SENSITIVITY |
1 copy |
| REPRODUCIBILITY |
CV<0.5% |
| CORRELATION COEFFICIENT |
-0.999 to -1.000 |
| LINEARITY RANGE |
100~1010 |
| RESOLUTION |
Can discriminate between 500 copies and 1000 copies |
| EXCITATION |
CH1 470nm CH2 530nm CH3 580nm
CH4 630nm CH5/CH6 custom-made |
| EMISSION |
CH1 510nm CH2 565nm CH3 620nm
CH4 665nm CH5/CH6 custom-made |
| SOFTWARE APPLICATION |
Absolute Quantification(AQ) ,Positive/Negative,Allelic Discrimination(TaqMan ®endpoint method ),Melting Curve analysis(FRET),Relative Quantification(RQ) /Gene expression analysis,High Resolution Melting Curve analysis,Isothermal Amplification |
| HOT-LID |
30~106℃(default 105℃,adjustable),electronic automatic hot-lid |
| POWER SUPPLY |
230VAC,50HZ |
| POWER CONSUMPTION |
850VA |
| COMPUTER REQUIREMENT |
1GB RAM,CPU1.5GHz |
| DIMENSIONS |
38cm×52cm×25cm(W×D×H) |
| WEIGHT |
18kg |
| OPERATION SYSTEM |
Windows XP,Windows Vista,Windows7 |
| COMMUNICATION |
RS232,USB |
|
| |
|
| Features of SLAN®-96P |
| |
| ● Innovative dual 48/48 reaction blocks-increased efficiency and flexibility |
| SLAN-96P's dual 48/48 reaction blocks are controlled separately,like two independent instrument.With SLAN-96P,two different assays can be tested simultaneously on a single instrument or a new assay can be started while another is running. |
| ● Patented precise-temperature-control technology:well-to-well uniformity with an accuracy of +/-0.1℃ |
| Benefit from its patented advanced temperature spot-to-spot compensation technology,The SLAN-96P's temperature uniformity across 96 wells is to within a remarkable +/-0.1℃.This superior uniformity meets all your needs for highly precise studies,especially for High-Resolution Melting Curve(HRM) application. |
 |
| ● Advanced fluorescence detection system-reliable,sensitive and calibration-free |
- The unique side-capture signal collection technology enhances fluorescence capture efficiency and eliminates signal noise,offering better detection sensitivity and smooth amplification curves;
- The improved optical system decreases instrument background ensuring better reproducibility;
- Long-lasting high-intensity LEDs which are reliable and maintenance-free;
- Negligible optical background resulting in no background calibration being required;
- Innovative optical light-path design eliminating edge effect and giving uniform fluorescence intensity for each tube,No ROX reference calibration is required;
- Instrument hardware calculates gain automatically during running.No gain setting is required;
- Professional optical filter combinations eliminate crosstalk between FAM,HEX,ROX,and CY5 channels.NO crosstalk calibration needed.
|
| ● Much faster-generates accurate results in less than 50 minutes |
| Basded upon the original SLAN system,the latest SLAN-96P has improved upon its thermal design with a super-fast heating/cooling rate of up to 4.5℃/S. |
| ● Professional multiplex detection channels-true 6plex real-time PCR |
| SLAN-96P's 6 sets of excitation and emission filter combinations ensure 6-color multiplexing real-time reading capacity;you will enjoy a high flexibility in the choice of fluorescence dyes and detection format. |
| ● Ideal approach to your HRM study-accurate,sensitive,no need for complicated temperature shift calibration |
- Fast fluorescence detection mode completes gene scanning in 30mins;
- Advanced hardware design and software algorithms generate and precise date without the need for temperature shift calibration.
|
| ● Outstanding performance-reduces experimental error |
- Correlation coefficient: -0.999~ -1.000
- Sensitivity:detection of one starting template copy
- High resolution:easily discriminates between 500 and 1000 copies
- Reproducibility:CV<0.5%
- Broad dynamic range:100~1010 copies
|
 |
| ● Powerful yet easy to use multitasking software-excellent tools for high-quality data analysis |
- A broad range of analysis applications:Quantification/Qualification,Allelic Discrimination,Melting Curve analysis,Relative Quantification,HRM,Isothermal Amplification;
- Unique protocol manager,a flexible and powerful tool for the management of assay protocols ;
- Unique rule function for easy result interpretation;
- Simple import and export functions enable integration with LIMS;
|
 |
| ● Support and service-we are committed to provide a better solution! |
- 18 month guarantee;
- Rapid customer and instrument support service;
- Highly stable and durable;high performance at an affordable price;
- Low noise,low power consumption,robust,compact and elegant;